Who can move the robot?
The Agent checks motion permission, the operator e-stop, and resource ownership. A second client cannot take over an arm while another client owns its motion.
What trips a guard?
A battery guard can require at least 10% charge and a reading no more than one second old. Crossing the threshold or losing fresh feedback latches the guard, blocks new motion, and starts stopping active work.
What if commands go quiet?
A teleop watchdog halts the base when velocity commands stop arriving within the granted interval. If the application disconnects, the Agent stops and cleans up the motion that client owned.
How is rest verified?
For an arm, each joint must stay within its configured velocity limit for the required dwell time. The Agent checks both reported speed and changes in measured position. Repeated copies of one sample cannot satisfy the check.
What if verification fails?
Further motion is blocked when cleanup cannot be verified. The Agent keeps that inhibit in place for recovery. Restarting the application does not clear it.
When can the task resume?
Resetting a tripped application guard requires fresh feedback inside its limits. The e-stop and any other inhibits still apply. Once motion is permitted, the application must submit a new operation.